Technical Overview

Function of a hydraulic main pump

How split double-pump circuits allocate flow and pressure in excavators

Flow Split
Hydraulics
Control Circuits

To understand an excavator’s operation, one must understand how its hydraulic circuit functions. The engine generates mechanical torque, but this rotation is completely converted by the **hydraulic main pump** into fluid power (represented by flow and pressure). The pump does not just generate pressure blindly; its primary function is to distribute fluid dynamically across independent circuits to ensure smooth, simultaneous movements.

In this technical guide, we break down the operational function of the main pump, how modern tandem (double-pump) designs divide flow to prevent lagging, and the difference between the low-pressure pilot circuit and high-pressure main circuit.

1. The Primary Function: Torque-to-Fluid Power Transmission

A common misconception is that a hydraulic pump creates pressure. In fluid dynamics, a pump generates **flow** (oil displacement per minute). **Pressure** is created only when that flow meets resistance (such as lifting a boom, pushing against dirt, or turning a motor).

The primary function of the main pump is to manage the transition between flow and pressure to optimize engine output:

01

Mechanical Input Intake

The diesel engine spins the pump’s input shaft at a set RPM. This rotational energy is transferred directly to the pump cylinder barrel, which houses the axial pistons.

02

Generating Pressurized Flow

The pistons sliding against the angled swashplate draw oil from the reservoir and force it out into the main control block. As oil meets the resistance of the heavy boom or bucket load, pressure builds up in the circuit.

03

Power Regulation (Torque Limiting)

The pump regulator monitors this pressure. If the digging resistance becomes too high, the regulator decreases the swashplate angle (reducing flow) to prevent the torque requirement from exceeding engine horsepower. This is known as constant horsepower control.

04

Actuator Speed Control

By altering swashplate displacement, the pump functions as an infinitely variable transmission. The operator controls the flow rate using the joysticks, which adjust actuator speeds (how fast cylinders extend) independently of engine RPM.

2. The Double-Pump Design: Preventing Circuit Starvation

On mini-excavators and larger crawler excavators, the main pump is actually a **double-pump** (or tandem pump) assembly. Inside a single housing, two separate axial piston pump groups (Pump 1 and Pump 2) are driven by the same engine shaft.

If an excavator used only a single pump for all movements, fluid would always take the path of least resistance. If you tried to raise the boom (heavy resistance) while curling the bucket (light resistance), all the oil would flow to the bucket cylinder, and the boom would stop moving. Additionally, straight travel would be impossible if one track met more resistance than the other.

The tandem design solves this by splitting the excavator into two independent circuits:

  • Pump 1 Circuit: Typically feeds the right travel motor, the bucket cylinder, and half of the main control block spool valves.
  • Pump 2 Circuit: Typically feeds the left travel motor, the arm (dipper) cylinder, the swing motor, and the other half of the main control block.
  • Flow Merging (Straight Travel & Boom Boost): When traveling in a straight line, Pump 1 and Pump 2 drive their respective tracks independently. When a high-speed movement is required (like raising the boom quickly), merge valves in the Main Control Valve (MCV) combine the flow of both Pump 1 and Pump 2 to double the actuator speed.

3. Main Control Circuits vs. Pilot Control Circuits

An excavator’s hydraulic system is divided into two distinct operating networks, each powered by different pump functions:

  • The Main High-Pressure Circuit: Powered by Pump 1 and Pump 2. This is the muscle of the machine, operating at pressures between **300 and 380 bar**. It routes thick hoses directly to the heavy boom, arm, bucket, swing motor, and travel final drives.
  • The Pilot Low-Pressure Circuit: Powered by a small gear pump mounted on the back of the main pump. This is the nervous system, operating at a constant pressure of **35 to 40 bar**. When the operator moves a joystick, pilot oil travels through thin lines to push the large main spool valves inside the MCV. This pilot oil controls the direction and volume of the main high-pressure oil without requiring heavy mechanical levers.

4. Circuit Flow Allocation Matrix

This matrix outlines how pump flow is distributed across the excavator’s primary circuits and the diagnostics of a failing pump group:

Circuit / Function
Pump Flow Allocation
Operational Role & Failure Diagnostics


Travel Circuit (Tracks)
Pump 1 drives the right travel track; Pump 2 drives the left travel track.
Ensures straight tracking. If one pump group is worn and bypassing internally, the excavator will drift or pull toward that side. Read about tracking speed differences.


Boom & Arm Cylinders
Combines flow from both Pump 1 and Pump 2 via internal merge valves for high-speed operation.
Powers boom lift and arm reach. If both pump groups are worn, digging cycles become slow and sluggish under load.


Bucket Cylinder
Driven primarily by Pump 1 flow.
Powers bucket breakout force. If Pump 1 fails, the bucket will lack curling force and struggle to break hard clay or rock.


Swing Motor
Driven by Pump 2 flow.
Rotates the excavator’s upper structure. Sticking regulator spools on Pump 2 cause sluggish swing start or jerky rotation.


Joystick Controls
Fed exclusively by the pilot gear pump.
Controls main spool shifting. Wear on the pilot gear pump causes low pilot pressure, resulting in stiff joysticks and unresponsive controls.

Regulator Diagnostic Tip:
If your excavator engine stalls immediately when a joystick is pulled to its limit (e.g. curling the bucket completely), the pump regulator valve is sticking. It is failing to destroke the swashplate under load. If all functions work but are extremely slow, the regulator is stuck in minimum stroke. Check out our final drive troubleshooting matrix to separate pump issues from final drive issues.

Frequently Asked Questions About Hydraulic Pump Functions

What is the main function of an excavator’s main hydraulic pump?
The main function of the hydraulic pump is to convert the mechanical rotational power of the engine into hydraulic fluid power (pressurized flow). This pressurized oil is directed by the main control valves to actuate cylinders and hydraulic motors, enabling the excavator to dig, swing, and travel.

Why do excavators use a double-pump (tandem) design instead of a single pump?
Excavators use a double-pump design (often two main piston pumps driven by one shaft) to separate and control independent circuits. This allows the operator to perform multiple movements simultaneously, such as traveling in a straight line while raising the boom, without one circuit stealing all the oil flow and causing lagging.

What is the difference between hydraulic flow and hydraulic pressure?
Hydraulic flow (measured in L/min or GPM) determines the speed of the excavator’s movements (how fast a cylinder extends). Hydraulic pressure (measured in bar or PSI) determines the force or digging power of the movement (how hard the bucket can break through soil). Pump regulators adjust flow dynamically to match pressure demands.

How does a pilot pump differ from the main hydraulic pump?
The main hydraulic pump is a variable displacement piston pump operating at high pressures (up to 350+ bar) to handle heavy physical work. The pilot pump is a small, fixed-displacement gear pump operating at constant low pressure (around 35-40 bar) to supply control oil to the joysticks, shifting the main spool valves when operated.

What happens when a hydraulic pump regulator sticks?
If a pump regulator sticks in maximum flow (high displacement), the engine will immediately bog down or stall when the excavator faces a heavy digging load. If the regulator sticks in minimum flow (low displacement), the excavator will operate extremely slowly, lacking responsive speed across all functions.

Related Technical Guides & Internal Link Building

To diagnose and protect your excavator’s powertrain, explore our technical library. If your machine pulls to one side, consult our guide on signs of a bad final drive, or check our hydraulic main pump overview to learn about pump styles. For travel motor diagnostics, read about final drives vs. travel motors.

To replace parts correctly, refer to how to replace a final drive or see how to repair a final drive. Before ordering components, confirm dimensions with how to measure a final drive correctly, and prevent wear by following our final drive maintenance guide.

Browse our extensive hydraulic spare parts inventory or return to the Mecatra blog overview for more technical guides. For help, quotes, or direct technical support from our facility in Horsens, Denmark, fill out the form below or email our team at info@mecatra.com.

Send a request
Get a quote
Send us your machine model and we’ll reply within 1-3 business hours.

Drag & drop or click to uploadJPG, PNG, PDF · Up to 5 files · Max 10 MB each


Need a spare part?

Find your component.

Final drives, hydraulic pumps, and swing devices in stock for 2,000+ machine models. Worldwide shipping within 24 hours.
Explore products
Contact us

2.000+
Machine models
30+
Countries served
24h
Dispatch

This website uses cookies. By continuing to use this site, you accept our use of cookies.